Products

- Energz UPS

Myria Series UPS 60-200kW

High Reliability

  • Wide input voltage and frequency range with high grid
    adaptability and prolong battery life.
  •  Separate internal air channel which hot air drives directly
    towards heat sink without distressing the PCB’s and other
    internal sensitive components, improving the components
    service life and UPS reliability
  • High overload capacity on inverter and bypass
  • The most advanced and dual DSP control prevents single
    failure point and increase performance.
  • Intelligent fan control and redundant design: 15% load can be
    driven when 2 fans fail and 40% load when 1 fan fails
  •  Integrated with input,output,bypass breaker and manual bypass
    switch for better protection of system.
  •  All-round conformal coating to all PCB boards, protect
    electronics from environmental effection and corrosion.
  •  High short circuit capacity with time duration settable from
    20~200ms which provide high protection for system.
  •  Cold start function which allow UPS start on battery when grid
    isn’t available.
  • Bus synchronization control function provides reliable high
    power for dual bus application
  •  Power walk in function decrease the inrush to mains or
    generator.
  • Start up delay function,to sequentially restart the rectifires once the mains power supply is restored if there are several UPS within the overall system
  •  No derating operate up to 40°C and continiously running under
    high ambient temperature up to 50°C with auto-derating

1.Power unit
2.Bypass and control unit
3.Power distribution unit

Green Power

  • Advanced IGBT and three level technology, Low harmonic,
    high efficiency,effectively energy-saving
  • High power density design, which small footprint on 100KW
    only 0.38m² for saving installation space.
  •  High input power factor up to 0.99 and low Input THDi: < 3.0%
    at full load, much less grid pollution and costs
  • AC/AC efficiency up to 96.5% and 30% load up to 95% efficiency reduces heat dissipation and limits power consumption costs
  • Eco mode efficiency up to 99.2% lead to significant cost reduction
  • W-ECO mode could reach 98.5% efficiency, THDI below 5% and transfer time below 4ms to reduce TCO
  •  Self-load test function, easy debugging and easy onsite test
    during commissioning, before it is connected the real load,
    without using costly temporary loads, cabling and breakers for
    energy saving.
  • Parallel ECO mode maximum whole system effciency.
  • Intelligent sleep mode which UPS sleep in random keep
    maximum efficiency and energy saving
  •  8 units of intelligent paralleling helps to achieve maximum
    capacity up to 1.6MW.

Intelligent Management 

  • Fault Trace Management (FTM) for convenient failure analysis
    (waveform record before & after of the fault point for 200ms)
    which easily figure out faulty point
  •  3 stage battery charging prolong the service life of batteries
  •  Intelligent battery management and mutiple setting, ±14~±24
    pcs batteries per string allow customers to get the faulty
    battery out instead of replacing it
  • Key components pre-alarm function which precaution the
    system fault and remind service for key components, like
    capacitor, fan.
  •  Full asset management record the spare parts replacement,
    timeline and service people.
  • Cabinet temperature detect and pre-notification which prevent over temperatur
  •  Smart programmable dry contact which have 5 input dry
    contact and 3 output dry contact, which input dry contact
    have more than 10 functions and output dry contact have 18
    functions allows to settable at site.
  • Smart generator mode which allow UPS sent signal to turn
    on and off generator, also taking part power from battery to
    compensation generator capacity.
  •  Self-dedusting function which save the preventive service
    time.
  •  Common battery bank on parallel mode.
  •  Frequency converter function (60Hz to 50Hz or 50Hz to 60Hz)
  •  VRLA and Lithium battery compatible design

More Options

  •  Flexible Network Management: SNMP
  •  Expanded dry contact kit (4 in 4 out)
  •  BMS kit for lithium battery communication
  •  Intelligent Battery Monitoring System
  •  Battery tripping kit
  •  N+X in parallel
  •  Input and output isolation transformer
  •  SPD: C Grade
  •  Battery Charge Temperature Compensation