Brief
The Energz High Joiner (7.5KW -20KW) air cooled series provides professional cooling solutions for base stations and small to medium-sized machine rooms, etc. As an important part of a machine room, it is designed to match the environment in which the equipment is located, configures with a constant temperature and humidity function, and features high airflow rate, low enthalpy difference and a high sensible heat ratio, soas to realize maximum reliability, long service life, and high energy efficiency and thus ensure the all-weather and energy- efficient operation of units.
Application
- Base stations
- Small and medium-sized machine rooms
- Small and medium-sized storage rooms and laboratories
- Small data room
Customer Value
Highly efficient – saving money
- High energy efficiency ratio, high sensible heat ratio, efficient refrigeration, and high energy efficiency
- High quality condenser, compact design, light weight, and convenient for installation, operation and maintenance
- An EC fan with high airflow rate, R410A environment-friendly refrigerant as a standard configuration, advanced noise reduction, and energy efficiency
- Self-contained quick couplings requiring no welding, facilitating flexible installation, and efficient operation and maintenance
- Compact design, small footprint, and optimized structure, greatly saving machine room space and reducing ownership costs for customers
- Low power consumption wet film humidifier, energy saving, wide application range.
Highly intelligent – time-saving
- An electrode humidifier is used to realize high humidification efficiency and a wide application range
- Capable of on-site monitoring and remote monitoring, ensuring efficient operation and maintenance
- Standard RS485 interface, local and remote monitoring
- A complete set of self-check, alarm and protection functions
- Intelligent control system, centralized control over multiple machines and featuring timing patrol and automatic failsafe
- Ultra-wide power grid adaptabilty, featuring phase sequence protection, self-starting when power is restored, and delayed start.
- Chinese LCD screen, multi-level password permission, self-check diagnosis function for management experts in the air conditioning field, and easy operation and maintenance
- The indoor unit adopts 100% front maintenance and a pull-out module design, greatly improving operation and maintenance efficiency.
Highly reliable – worry-free
- Efficient and refiable compressor used to ensure the reliabilty of system operation
- 24 hours x 365 days full-time operation, designed with a ten-year lifespan, low operation and maintenance costs.
- Ultra-wide operating temperature range (outdoor- -35°C to 45°C); operation under ultra-low temperatures is possible for outdoor installations
Technical Specifications
| K A B 8 AU | K J A- PBAU | KHJ A- B12A U | KH JA- 12 AU | K JA- B 20 | K J A P 20 A U | |
| Main power | 380V/3PH/50Hz | |||||
| Air supply mode | Upward | |||||
| Cooling capacity (kW) | 7.5 | 7.5 | 12.5 | 115 | 20.0 | 20.0 |
| Realistic capacity (kW) | 6.8 | 6.8 | 11.3 | 11.3 | 18.0 | 18.0 |
| Circulating air volume (m’/h) | 2300 | 2300 | 3600 | 3600 | 5400 | 5400 |
| Heating capacity (kW) | / | 3 | 3 | 3 | ||
| Numidifying capacity (kg/h) | 1.S | 1.S | 2 | |||
| Width (mm) | 550 | 550 | 650 | 650 | 800 | 800 |
| Depth (mm) | 4S0 | 4S0 | 450 | 450 | 650 | 650 |
| Height (mm) | 1800 | 1800 | 1800 | 1800 | 1800 | 1800 |
| Max. operating current (A)
Weight (kg) |
8.4
112 |
13.0
î18 |
11.9
132 |
16.5
138 |
21.8
168 |
26.3
174 |
| hH N R 8 | H N R 8 | HN 12 | K | N | 12 | HN | 0 | K N 20 | |
| Main power | 220V/1PH/50Hz | ||||||||
| Width (mm) | 728 | 728 | 728 | 1080 | 1080 | ||||
| Depth (mm) | 405 | 405 | 405 | 405 | 405 | 405 | |||
| Height (mm) | 762 | 762 | 1372 | 1372 | 1372 | 1372 | |||
| Weight (kg) | 34 | 34 | 53 | 53 | 85 | 85 | |||
Notes:
- Unit return air condtion: 1. Indoor return air: 24°C/50%RH, outdoor: 35°C. 2. Indoor return air: 37°C/26%RH, outdoor: 35°C.
- The unit comes standard with R410A refrigerant, EC fan, and electronic expansion valve
- Air supply method: The standard air supply method is a sinking fan air supply, and optional wind cap upward air supply and semi-sinking fan air supply are available.
- The size and weight of the outdoor unit in the table above are parameters for a single outdoor unit. The 60kW/80kW/100kW is a dual-system model, and each indoor unit is configured with two outdoor units The height of the outdoor unit does not include support feet .
- For details on the centralized outdoor unit with an integrated freon pump, please see the outdoor unit promotion page.