High Reliability
- Wide input voltage and frequency range with high grid
adaptability and prolong battery life. - Separate internal air channel which hot air drives directly
towards heat sink without distressing the PCB’s and other
internal sensitive components, improving the components
service life and UPS reliability - High overload capacity on inverter and bypass
- The most advanced and dual DSP control prevents single
failure point and increase performance. - Intelligent fan control and redundant design: 15% load can be
driven when 2 fans fail and 40% load when 1 fan fails - Integrated with input,output,bypass breaker and manual bypass
switch for better protection of system. - All-round conformal coating to all PCB boards, protect
electronics from environmental effection and corrosion. - High short circuit capacity with time duration settable from
20~200ms which provide high protection for system. - Cold start function which allow UPS start on battery when grid
isn’t available. - Bus synchronization control function provides reliable high
power for dual bus application - Power walk in function decrease the inrush to mains or
generator. - Start up delay function,to sequentially restart the rectifires once the mains power supply is restored if there are several UPS within the overall system
- No derating operate up to 40°C and continiously running under
high ambient temperature up to 50°C with auto-derating
1.Power unit
2.Bypass and control unit
3.Power distribution unit
Green Power
- Advanced IGBT and three level technology, Low harmonic,
high efficiency,effectively energy-saving - High power density design, which small footprint on 100KW
only 0.38m² for saving installation space. - High input power factor up to 0.99 and low Input THDi: < 3.0%
at full load, much less grid pollution and costs - AC/AC efficiency up to 96.5% and 30% load up to 95% efficiency reduces heat dissipation and limits power consumption costs
- Eco mode efficiency up to 99.2% lead to significant cost reduction
- W-ECO mode could reach 98.5% efficiency, THDI below 5% and transfer time below 4ms to reduce TCO
- Self-load test function, easy debugging and easy onsite test
during commissioning, before it is connected the real load,
without using costly temporary loads, cabling and breakers for
energy saving. - Parallel ECO mode maximum whole system effciency.
- Intelligent sleep mode which UPS sleep in random keep
maximum efficiency and energy saving - 8 units of intelligent paralleling helps to achieve maximum
capacity up to 1.6MW.
Intelligent Management
- Fault Trace Management (FTM) for convenient failure analysis
(waveform record before & after of the fault point for 200ms)
which easily figure out faulty point - 3 stage battery charging prolong the service life of batteries
- Intelligent battery management and mutiple setting, ±14~±24
pcs batteries per string allow customers to get the faulty
battery out instead of replacing it - Key components pre-alarm function which precaution the
system fault and remind service for key components, like
capacitor, fan. - Full asset management record the spare parts replacement,
timeline and service people. - Cabinet temperature detect and pre-notification which prevent over temperatur
- Smart programmable dry contact which have 5 input dry
contact and 3 output dry contact, which input dry contact
have more than 10 functions and output dry contact have 18
functions allows to settable at site. - Smart generator mode which allow UPS sent signal to turn
on and off generator, also taking part power from battery to
compensation generator capacity. - Self-dedusting function which save the preventive service
time. - Common battery bank on parallel mode.
- Frequency converter function (60Hz to 50Hz or 50Hz to 60Hz)
- VRLA and Lithium battery compatible design
More Options
- Flexible Network Management: SNMP
- Expanded dry contact kit (4 in 4 out)
- BMS kit for lithium battery communication
- Intelligent Battery Monitoring System
- Battery tripping kit
- N+X in parallel
- Input and output isolation transformer
- SPD: C Grade
- Battery Charge Temperature Compensation